RS1082CL.pdf

(139 KB) Pobierz
Transmitter Tetrode
RS 1082 C
YL 1011/YL 1012
For single-sideband transmitters and TV transmitters
Coaxial metal-ceramic tetrode for frequencies up to 250 MHz, forced-air-cooled or vapor-cooled,
particularly suitable for single-sideband transmitters in professional communications engineering,
for broadcast transmitters up to 50 kW and TV transmitters, band III.
Forced-air-cooled version
RS 1082 CL
Ordering code Q51-X1082
Vapor-cooled version
RS 1082 CV
Ordering code Q53-X1082
FRAME4/home/SMC-Archiv-DB/GG-RO-engl/DB-Senderoehren-96_BNR-B442-P4213-X-X-
Dimensions in mm
Do not use as terminal
Taphole M5 for tube fuse RöSich1
Handle, swingable
Taphole M6 for screw-in handle RöZub31V
Taphole M5 for tube fuse RöSich4
Approx. weight 16 kg
Approx. 14,5 kg
90
Siemens Aktiengesellschaft
Transmitter Tetrode
RS 1082 C
Heating
Heater voltage
Heater current
Heating: direct
Cathode: thoriated tungsten
Characteristics
Emission current
at
U
A
=
U
G2
=
U
G1
= 500 V
Amplification factor of screen grid
at
U
A
= 3 kV,
U
G2
= 800 to 1200 V,
I
A
= 2,5 A
Transconductance
at
U
A
= 3 kV,
U
G2
= 1200 V,
I
A
= 2,5 A
Capacitances
Cathode/control grid
Cathode/screen grid
Cathode/anode
Control grid/screen grid
Control grid/anode
Screen grid/anode
Accessories
RS 1082 CL
Internal cathode terminal
External cathode terminal
Header socket for cathode and control grid
with cathode blocking
Control grid terminal
Screen grid terminal
Screen grid terminal with blocking
SW header socket with screen grid blocking
against control grid
SW header socket with screen grid blocking
against cathode
Socket wrench for tube fuse
Tube fuse
Pull switch for tube fuse
Joining piece for air duct
RöKat82a
RöKat82b
RöKat82c
RöGit82a
RöGit82b
RöGit82d
RöKpf82G
RöKpf82K
RöZub10
RöSich1
RöKt11
RöAnst360
U
F
I
F
10
≈
200
V
A
I
em
µ
g2g1
80
6,6
A
s
65
mA/V
c
kg1
c
kg2
c
ka
c
g1g2
c
g1a
c
g2a
≈
125
≈
10
≈
0,2
≈
155
≈
1,6
≈
40
pF
pF
pF
1
)
pF
pF
1
)
pF
Ordering code
Q81-X1182
Q81-X1184
Q81-X1183
Q81-X982
Q81-X983
Q81-X985
Q81-X1852
Q81-X1851
Q81-X2110
Q81-X1401
Q81-X1311
Q81-X744
1) Measured by means of a 40 cm
×
40 cm screening plate in the screen grid terminal plane.
Siemens Aktiengesellschaft
91
Transmitter Tetrode
RS 1082 C
Accessories
RS 1082 CV
Mounting instruction
Mounting instruction
Internal cathode terminal
External cathode terminal
Header socket for cathode and control grid
with cathode blocking
Control grid terminal
Screen grid terminal
Screen grid terminal with blocking
SW header socket with screen grid blocking
against control grid
SW header socket with screen grid blocking
against cathode
Socket wrench for tube fuse
Handle
Tube fuse
Pull switch for tube fuse
Boiler
Insulating pipe at water inlet
Union at water inlet
Insulating pipe at vapor outlet
Gasket at vapor outlet
Insulator
Water level stabilizer with control
electrodes
LL electrolytic target
Gasket for boiler
RöMo64
RöMo75
RöKat82a
RöKat82b
RöKat82c
RöGit82a
RöGit82b
RöGit82d
RöKpf82G
RöKpf82K
RöZub10
RöZub31V
RöSich4
RöKt11
RöKüV221
RöKüV31Zub4
RöKüV31Zub7
RöKüV201Zub3
RöKüV201Zub8
RöKüV221Zub5K
RöZubV4
RöEl21
RöN9373
Ordering code
Q81-X1182
Q81-X1184
Q81-X1183
Q81-X982
Q81-X983
Q81-X985
Q81-X1852
Q81-X1851
Q81-X2110
Q81-X2133
Q81-X1404
Q81-X1311
Q81-X1681
Q81-X1634
Q81-X1637
Q81-X1673
Q81-X1678
Q81-X1686
Q81-X2105
C65055-A667-A21
C65051-A182-C506
92
Siemens Aktiengesellschaft
Transmitter Tetrode
RS 1082 C
Anode and screen grid modulation,
class C operation, grounded cathode circuit
Maximum ratings
Frequency
Anode voltage (dc)
Screen grid voltage (dc)
Control grid voltage (dc)
Cathode current (dc)
Peak cathode current
Anode dissipation
Anode dissipation
Screen grid dissipation
Control grid dissipation
Operating characteristics
Frequency
Carrier power
Anode voltage (dc)
Screen grid voltage (dc)
Control grid bias (dc), fixed
Control grid resistance
Peak control grid voltage (ac)
Anode current (dc)
Screen grid current (dc)
Control grid current (dc)
Anode input power
Drive power
Anode dissipation
Screen grid dissipation
Control grid dissipation
Efficiency
Anode load resistance
Modulation factor
Peak screen grid voltage (ac)
Modulation power
Control grid current (dc)
Drive power
Anode dissipation at modulation
Screen grid dissipation at modulation
(RS 1082 CL)
(RS 1082 CV)
f
U
A
U
G2
U
G1
I
K
I
K M
P
A
P
A
P
G2
P
G1
f
P
trg
U
A
U
G2
U
G1 fix
R
G1
U
g1 m
I
A
I
G2
I
G1
P
B A
P
1
P
A
P
G2
P
G1
η
R
A
m
U
g2 m
P
mod
I
G1
P
1
P
A mod
P
G2 mod
30
10,5
900
– 500
15
80
30
45
600
300
≤
30
55
10
800
– 340
300
610
6,9
0,5
0,36
69
200
14
400
40
80
780
100
600
35
0,51
280
23
400
MHz
kV
V
V
A
A
kW
kW
W
W
MHz
kW
1
)
kV
V
V
Ω
V
A
A
A
kW
W
1
)
kW
2
)
W
W
%
Ω
%
V
3
)
kW
A
4
)
W
1
)
4
)
kW
5
)
W
5
)
1) Circuit losses are not included.
2) Even during modulation the indicated maximum ratings must not be exceeded. It has to be observed that the plate dissipation
will increase to about 1,5 times the power dissipation stated for the carrier value during 100 % modulation.
3) Modulation of screen grid via separate transformer winding.
4) Maximum values at
U
A
= 0 V.
5) Average values at
m
= 100 %.
Siemens Aktiengesellschaft
93
Transmitter Tetrode
RS 1082 C
RF linear amplifier,
SSB modulation, grounded cathode circuit,
I
G1
= 0
Maximum ratings
Frequency
Anode voltage (dc)
Screen grid voltage (dc)
Control grid voltage (dc)
Cathode current (dc)
Peak cathode current
Anode dissipation
Anode dissipation
Screen grid dissipation
Control grid dissipation
Operating characteristics
Output power
Anode voltage (dc)
Screen grid voltage (dc)
Control grid voltage (dc)
Peak control grid voltage (ac)
Anode current (dc)
Screen grid current (dc)
Anode input power
Anode dissipation
Screen grid dissipation
Efficiency
Third order intermodulation product
Fifth order intermodulation product
III
III
III
No modulation
1-tone modulation
2-tone modulation
(RS 1082 CL)
(RS 1082 CV)
f
U
A
U
G2
U
G1
I
K
I
K M
P
A
P
A
P
G2
P
G1
I
30
12
1400
– 350
15
80
30
45
600
300
II
1
)
33
10
1200
– 185
160
5,2
250
52
19
300
63
–
–
MHz
kV
V
V
A
A
kW
kW
W
W
III
1
)
16,5
10
1200
– 185
160
3,3
80
33
16,5
96
50
≥
36
≥
44
kW
2
)
kV
V
V
V
A
mA
kW
kW
W
%
dB
3
)
dB
3
)
P
2
U
A
U
G2
U
G1
U
g1 m
I
A
I
G2
P
B A
P
A
P
G2
η
d
3
d
5
0
10
1200
– 185
0
2,0
0
20
20
0
–
–
–
1) Carrier suppressed.
2) Circuit losses are not included.
3) Level of non-linear cross talk resulting from third and fifth order intermodulation products as measured by the 2-tone method at
f
= 30 MHz.
94
Siemens Aktiengesellschaft
Zgłoś jeśli naruszono regulamin