05–884
DIAGNOSTICS
AIR CONDITIONING SYSTEM
050TM–17
PROBLEM SYMPTOMS TABLE
If a normal system code is displayed during the DTC check but the problem still occurs, check the circuits
for each problem symptom in the order given in the table below and proceed to the relevant troubleshooting
page.
HINT:
Inspect the ”Fuse” and ”Relay” before inspecting the suspected area as shown in the table below.
Inspect each malfunction circuit in numerical order for the corresponding symptom.
If the malfunction still exists even after checking and confirming that all the circuits are normal, replace the
A/C amplifier.
Symptom
Entire A/C system does not operate
Suspected Area
1. IG power source circuit
2. A/C amplifier assy
1. Blower motor controller
2. Blower motor
3. A/C amplifier assy
Air Flow Control: No blower control
1. Blower motor controller
2. A/C amplifier assy
1. Volume of refrigerant
2. Drive belt tension
3.
4.
5.
6.
1ZZ–FE/3ZZ–FE
1CD–FTV
Refrigerant pressure
Compressor solenoid circuit
Pressure switch circuit
Air mix damper control servomotor circuit
See page
05–926
05–881
05–936
05–936
05–881
05–936
05–881
55–20
14–6
55–41
55–20
05–960
05–942
05–914
05–906
05–886
05–890
05–881
05–1882
05–914
05–906
05–890
05–886
05–894
05–881
05–1882
05–886
05–890
05–898
05–914
05–906
05–881
05–1882
05–914
05–906
05–881
05–922
05–881
05–918
05–910
05–881
Air Flow Control: No blower operation
Temperature Control: No cool air comes out
7. Air mix damper position sensor circuit
8. Room temperature sensor circuit
9. Ambient temperature sensor circuit
10. A/C amplifier assy
11. Multiplex communication circuit
1. Air mix damper control servomotor circuit
2. Air mix damper position sensor circuit
3.
4.
5.
6.
7.
Ambient temperature sensor circuit
Room temperature sensor circuit
Evaporator temperature sensor circuit
A/C amplifier assy
Multiplex communication circuit
Temperature Control: No warm air comes out
8. Heater radiator
1. Room temperature sensor circuit
2.
3.
4.
5.
6.
Ambient temperature sensor circuit
Solar sensor circuit
Air mix damper control servomotor circuit
Air mix damper position sensor circuit
A/C amplifier assy
Temperature Control: Output air is warmer or cooler than set
temperature or response is slow
7. Multiplex communication circuit
Temperature Control: No temperature control
(only Max. cool or Max. hot)
No air inlet control
1. Air mix damper control servomotor circuit
2. Air mix damper position sensor circuit
3. A/C amplifier assy
1. Recirculation damper servomotor circuit
2. A/C amplifier assy
1. Air outlet damper control servomotor circuit
2. Air outlet damper position sensor circuit
3. A/C amplifier assy
No air outlet control
COROLLA VERSO REPAIR MANUAL (RM1100E)
05–885
DIAGNOSTICS
AIR CONDITIONING SYSTEM
05–960
05–881
05–1882
05–881
05–881
05–930
05–881
1. Compressor solenoid circuit
Engine idle up does not occur, or is continuous
Displayed set temperature value does not match up with operation
of temperature control switch
Brightness does not change when rheostat volume or light control
switch is adjusted
Unable to access the diagnosis mode
DTCs are not recorded. Set mode is cleared when engine switch
is turned off
2. A/C amplifier assy
3. Multiplex communication circuit
1. A/C amplifier assy
1. Illumination light system
1. A/C amplifier assy
1. Back–up power source circuit
2. A/C amplifier assy
PTC heater:
Symptom
The heater performance is low
(The PTC heater does not function)*1
Suspected Area
1. PTC heater circuit
2. A/C amplifier assy
3. Multiplex communication circuit
See page
05–942
05–881
05–1882
*1: The PTC heater operation may be stopped when an electrical load is high on the entire vehicle.
Hot gas heater:
Symptom
2.
3.
4.
5.
6.
Suspected Area
1. Volume of refrigerant
Warm air does not come out even if the gas heater switch is
turned on before the water temperature rises.
Refrigerant pressure
Hot gas heater switch circuit
Hot gas heater magnetic valve circuit
Hot gas heater relay circuit
A/C amplifier assy
See page
55–20
55–20
05–951
05–948
05–954
05–881
HINT:
The hot gas heater system used refrigerant.