LTMag-V16N3-23-LTspice_Transformers-MikeEngelhardt.pdf

(427 KB) Pobierz
DESIGN IDEAS
L
Using Transformers in
LTspice/SwitcherCAD III
Introduction
Transformers are a key component
in many switching regulator designs,
providing an isolation barrier in dan-
gerous high power systems, allowing
very high step-down or step-up ratios
in high voltage designs and (with an
extra winding) easily accommodating
multiple or inverting outputs. Flyback,
forward and SEPIC converters all make
use of transformers. This article tells
you what you need to know to add
transformers to LTspice/SwitcherCAD
III simulations.
by Mike Engelhardt
About LTspice/SwitcherCAD III
LTspice/SwitcherCAD III is a powerful SPICE simulation tool with inte-
grated schematic capture. Unlike many other free simulators, LTSpice is a
general purpose tool and not limited. LTspice includes models for most of
Linear Technology’s switch-mode DC/DC converters as well as a library of
devices for general analog circuit simulation including op amps, compara-
tors, linear regulators and discretes. LTspice/SwitcherCAD III is available
for free download at www.linear.com.
L
lows you to place text on the schematic
that is included in the SPICE netlist.
Once the inductor is mentioned in a
K-statement, LTspice uses an inductor
symbol with a visible phasing dot to
indicate each winding’s phasing.
Setting the turns ratio of the trans-
former is simply a matter of choosing
the right inductor values. Remember,
the inductance is proportional to the
square of the turns ratio. In the ex-
ample above, a turns ratio of 1:3 gives
a 1:9 inductance ratio.
The last entry of the K-statement is
the mutual coupling coefficient. This
is on a scale of 0 to 1 where 1 means
perfect coupling between the inductors
(i.e., no leakage inductance.) Leakage
inductance is usually not desired in
a practical circuit. For example, in
transformers that are intended to
store energy, such as in a flyback
converter, leakage inductance pre-
vents the secondary from removing all
of the energy stored by the primary.
In a non-energy storage transformer,
the leakage inductance’s impedance
can limit how well the secondary can
shield the core from the primary cur-
rent setting a hard limit on how much
energy can be transformed through
the transformer. Either way, leakage
inductance can cause undesired volt-
age spikes or ringing which can lead
Draw Each Winding
as an Inductor
Figure 1 shows the basic technique.
One simply draws each winding of
the transformer as an inductor and
couples the inductors with a SPICE
directive called a K-statement (e.g.,
“K1
L1 L2 1”.)
To add the directive, choose SPICE
Directive from the Edit menu. This al-
DESIGN IDEAS
Using Transformers in
LTspice/SwitcherCAD III ....................23
Mike Engelhardt
Miniscule Step-Up Controller Yields
Wide Input and Output Ranges .........25
Theo Phillips and Hong Ren
High Voltage Step-Down Controller
Delivers High Power with Minimum
Number of Components......................27
Stephanie Dai and Theo Phillips
94% Efficient, Low Noise, Step-Up
DC/DC Converter in 2mm × 2mm DFN
Package Offers Unrivaled Performance
and Solution Size ..............................29
Bert Hepfinger
Simple, High Efficiency, Multi-Output,
Isolated Flyback Supply with
Excellent Regulation .........................30
Ryan Huff
Monolithic Buck Regulator
Operates Down to 1.6V Input.............33
Gregg Castellucci
J-FET-Based DC/DC Converter Starts
and Runs from 300mV Supply ...........34
Jim Williams
Figure 1. To add a transformer to your LTSpice/SwitcherCAD III model,
simply draw two inductors and add a “K” statement to couple the inductors.
Linear Technology Magazine • September 2006
23
L
DESIGN IDEAS
to a requirement for snubbing circuits
and their associated energy losses.
We’ll get back to leakage inductance
later, but for an initial simulation, it’s
easier and often sufficient to ignore
leakage inductance by setting the
mutual coupling coefficient to 1.
Multiple Secondaries
When you have a transformer with
more than one primary and one
secondary you have to make sure
that all mutual inductances are in-
cluded. Consider a transformer with
four windings; L1, L2, L3 and L4. A
common error is adding only three
mutual couplings with three separate
K-statements for such a transformer
with four windings:
K1 L1 L2 1
K2 L2 L3 1
K3 L3 L4 1
LTspice will tell you that this
transformer is impossible since it isn’t
possible for L1 to be perfectly coupled
to L2 and L2 perfectly coupled to L3
without some coupling between L1 and
L3. Yes, it is possible for two induc-
tors to have no mutual inductance
yet have some coupling to a third,
but there are limits on how well they
can be coupled to that third. LTspice
analyzes the mutual coupling coef-
ficient matrix and determines if your
coupling coefficients are physically
realizable.
A transformer with four windings
usually has six non-zero mutual in-
ductances:
K1
K2
K3
K4
K5
K6
L1
L1
L1
L2
L2
L3
L2
L3
L4
L3
L4
L4
1
1
1
1
1
1
Figure 2. To add a transformer with more than two windings,
add a “K” statement that includes all of the coupled inductors.
inductance is tedious at best and
tends to be error prone. A better ap-
proach is to use a single K-statement
that mentions all the inductors that
are wound on the same core and let
LTspice do the work:
K1 L1 L2 L3 L4 1
LTspice understands this to mean
that all these inductors are coupled
to each other by the same mutual
coupling coefficient. Figure 2 shows
this technique used in a transformer
with four windings configured as an
autotransformer by connecting the
windings in series.
Leakage Inductance
You may want to simulate the effects
of leakage inductance in order to con-
sider snubber designs or work out the
commutation timing of a resonantly
switched converter. There are two
ways to add leakage inductance to
your model. You can either put extra
inductors in series with the leads of
the winding inductors—a very direct
approach—or use a mutual coupling
coefficient of less than one. The leakage
inductance, L
LEAK
, can be related to the
winding inductance, L, and coupling
coefficient, K, by the equation:
L
LEAK
= L • (1 – K • K)
If K is close to 1, the two methods
are electrically equivalent.
One note of caution: The modeling
effort increases significantly when
leakage is added, because once you add
leakage inductance to a simulation,
you also need to model the capaci-
tances that can ring with it and the
losses that limit the Q of the ringing,
in order to get any agreement between
simulated and measured effects. For
this reason, I usually recommend
starting simulating without any leak-
age inductance and then add it later
if you feel you need to investigate the
non-ideal behavior due to leakage
inductance in the transformer.
Conclusion
To simulate a transformer in your
LTspice/SwitcherCAD III simulations,
just draw each winding of the trans-
former as an individual inductor. Then
add a SPICE directive of the form
K1
L1 L2 L3 ... 1.
to the schematic.
That’s basically it!
For an example simulation file
using coupled inductors in a SEPIC
converter, visit the product page for
the LTC1871 controller at www.linear.
com and click on the Simulate tab
for a ready-to-run a demonstration
circuit.
L
Linear Technology Magazine • September 2006
In general, the number of mutual
inductances in a transformer with N
windings is N • (N – 1)/2. Note that
the number grows as N squared, just
like the inductance of each individual
winding is proportional to the square
of the number of turns.
Permuting all the inductor names
by hand to generate individual mutual
coupling statements for each mutual
24
Zgłoś jeśli naruszono regulamin