MANUAL_SW_2164C_english.pdf

(15465 KB) Pobierz
SOFTWARE MANUAL
LANDI RENZO OMEGAS
for
LRE 184 -188 -194 -198 - EVO
ECUs
Version 2.16.4 C
2012-07 *1* gb
Manuale software OMEGAS 2.16.4 C
UPDATES
Rev.
Date
Description of change
Performed by
Approved by
1
0
July 2012
November 2011
Page 5 ref.
First issue
1
I.Martinelli
I.Martinelli
3
4
4
4
4
4
5
6
9
9
15
17
18
20
22
24
27
30
33
37
38
41
44
46
48
50
51
52
53
54
Notes
Software
Minimum computer requirements for software
installation
Software distribution
Software installation
Software operation
Error codes software program
Software initial view
F1 Vehicle configuration
F1 Gas change over
F2 Lambda
F3 Emissions
F4 Gas level
F5 Pressure
F6 Temperature
F7 K insertion
F8 Injectors
F9
Gas/petrol
F10 Adaptivity
F11 Exit
F2 Dispaly
F3 Diagnosis
F4 Automatic calibration
Calibration fine tuning.
F5 Modify calibration
F6 Save current configuration
F7 Load New configuration
F8 ECU Programming
F9 Update cards and maps
F10 Exit
Index
The materials and documents of any nature contained and published in this Manual are for information and promotional purposes
only and, unless otherwise stated, are the sole property of Landi Renzo S.p.A. or its successors in title who retain worldwide copyright
for the entire duration of the protection offered by law; any other use that has not been expressly granted is forbidden. The Manual
and the materials contained therein cannot be reproduced, published, transmitted, distributed, publicly displayed, removed, cancel-
led, added to, modified, used to create derivative works, sold or acquired. Any other use of the material in this Manual, including
reproduction for purposes other than those it was intended for, modification, distribution or publishing is forbidden without the written
permission of Landi Renzo S.p.A.
This document is the property of LANDI RENZO. It cannot be distributed or copied without prior written approval
2
LANDI RENZO S.p.A.
Manuale software OMEGAS 2.16.4 C
NOTES
The software program described in this manual applies to
different types of ECU.
The software automatically recognises the connected ECU
by means of firmware that is loaded by the manufacturer
during the initial programming stage.
Certain program windows and functions are only visible/
available on some versions of ECUs. In such cases, the
words LROMEGAS or OMEGAS-EVO appear alongside
the function as do the customised icons that identify this
latest version.
As regards the
LROMEGAS
LRE184 -188 ECUs, refer also
to previous software manuals “Omegas 2.6.4” or earlier.
The
OMEGAS-EVO
version can be installed on 2-3-4 nor-
mally aspirated and turbocharged cylinder engines.
The MAP sensor that comes with the unit must always be
fitted.
At present, the combined injectors are series “AEB”
The field of application is described in the “Component In-
stallation Manual”.
A range of minimum/maximum settings is available for se-
lection.
WARNING
if you enter a value that is outside the range, the
maximum or minimum applicable value will be saved, not
the previously set value and no warning window will appear.
The boxes and drop-down menu open together when you
press the button for the box.
To activate any changes made to the program, press “En-
ter”.
The parameters in “RED” can be changed only if the ignition
is OFF as the software string at the bottom of the “F1 Ve-
hicle Configuration window; “F1 Gas change over” reminds
us.
To correctly save changes to the parameters in “RED” made
with the engine running, you need to:
- switch the engine off;
- wait until the switch is OFF (if delayed ignition);
- re-start the engine.
This document is the property of LANDI RENZO. It cannot be distributed or copied without prior written approval
3
LANDI RENZO S.p.A.
Manuale software OMEGAS 2.16.4 C
SOFTWARE
MINIMUM COMPUTER REQUIREMENTS FOR SOFTWARE INSTALLATION
Operating system - Windows 98 2nd edition or later;
RAM - At least 16 Mbyte;
Hard disk - At least 20 Mbyte free at time of installation;
Screen resolution - 800 x 600 or better;
Internet Explorer version 5.5 or better.
SOFTWARE DISTRIBUTION
LANDI RENZO S.p.A. distributes the software (and future up-dates) through the website “www.landi.it/private area/
download software programs” or on a CD.
SOFTWARE INSTALLATION
To install the calibration program, put the CD in the reader and wait for the installation wizard to appear.
If the installation program does not start, select “Start” from the “Application Bar”. Select “run” and enter: “D:\setup.
exe” (where D indicates the CD reader).
During installation you will be asked which directory you want to use for installation. We recommend that you use
the preset directory.
When installation is complete, an icon will appear on the desktop.
SOFTWARE OPERATION
The calibration software needs a specific hardware key and can be opened without being directly connected to the
ECU.
To connect to the ECU, the computer and ECU must be properly connected with a modular adaptor. Depending on
the characteristics of the computer, use the appropriate module: version for Serial/USB port; version for serial RS232
port; WIRELESS SERIAL KIT; USB/RS232 adaptor.
The ECU must also be powered with a 12 volt battery (Red/Black wire) and an earth connection (Black wire) and with
12V with the ignition ON (dashboard lights ON - engine OFF).
Open the program by selecting the specific icon on the computer screen.
This document is the property of LANDI RENZO. It cannot be distributed or copied without prior written approval
4
LANDI RENZO S.p.A.
Manuale software OMEGAS 2.16.4 C
SOFTWARE PROGRAM FAULT CODES
ERROR
PROGRAMMING
P01
P02
P03
P04
Cannot connect to ECU on COM or USB ports, cannot find a connected control unit.
The ECU is not communicating or the communication pathway is not complete.
The ECU connected is incompatible due to hardware or firmware.
Error opening the programming file.
Error in decryption of the programming file.
(The reprogramming procedure requires the presence of Internet Explorer 5.5 or higher, with at
least 128-bit cryptography).
Incorrect programming voltage.
Error in flash cancellation.
Error during initialisation (BAD_PREPARATION).
Error during initialisation (BAD_ERASE).
Error in start programming phase.
Null dimension in input data.
Incorrect encryption mode.
Generic programming error.
Firmware isn’t correct for the ECU connected.
Error in record programming (ERR.CODE-1000). Firmware writing was not successful, the pro-
gramming must be repeated.
DESCRIPTION
P05
P06
P07
P08
P09
P10
P11
P12
P13
(1-6)
from
P1000
HARDWARE KEY
H01
1
Error reading/writing hardware key.
Key with expired data or number of accesses.
Data not compatible with internal data of key.
H02
H03
H04
CONNECTION
C01
C02
C03
C04
1
Cannot connect to ECU on COM or USB ports, cannot find a connected control unit.
The control unit is not communicating or the communication pathway is not complete.
Error loading control unit identification data.
The firmware of the connected ECU is not compatible with the program installed on the PC.
The program installed on the PC is not compatible with the control unit firmware.
ECU in boot mode, you must reprogram it with a suitable FW
C05
This document is the property of LANDI RENZO. It cannot be distributed or copied without prior written approval
5
LANDI RENZO S.p.A.