SuperStack
®
3 Baseline Dual Speed Hub 16-Port TP (3C16410) and
24-Port TP (3C16411) User Guide
DUA1641-0AAA01
1
4 5
13
16
17
8 9
12
20 21
24
I
NTRODUCTION
The SuperStack
®
3 Baseline Dual Speed Hub is an easy-to-use, 10/100
autosensing Class II hub (repeater). It is ideal for users who want to
connect both Ethernet and Fast Ethernet devices (workstations and other
equipment) to the same hub.
All ports on the Baseline Dual Speed Hub are half duplex, autosensing
10 Mbps and 100 Mbps. Each port senses the speed of the connected
equipment and operates at the appropriate speed.
The Baseline Dual Speed Hub comes with:
One power cord for use with the Baseline Dual Speed Hub
Four standard height, self-adhesive rubber pads
One rack mounting kit
A warranty information sheet with details of online registration
The Baseline Dual Speed Hub is suitable for office use where it can be free
standing or rack-mounted (in a wiring closet or equipment room). The
hub is powered from the AC mains supply
Network Connections
The Baseline Dual Speed Hub has 16 or 24 shielded RJ-45, 10/100
autosensing ports on the front panel. Each port can be connected to
either a 10BASE-T (Ethernet) or a 100BASE-TX (Fast Ethernet) device.
Internally, the hub has two repeater segments (10 Mbps and 100 Mbps)
which are linked by a switch, allowing connected 10 Mbps and 100 Mbps
devices to communicate.
You can connect a 10BASE-T or 100BASE-TX hub or switch to the
Baseline Dual Speed Hub.
1
H
OW TO
U
SE THE
B
ASELINE
D
UAL
S
PEED
H
UB
1
1
4 5
8
9
12
2
3
4
13
16 17
20 21
24
6
5
7
Numbered elements in this diagram refer to numbered sections in the
text. These numbers, in bold, are used as references.
series, ensure that there are no more than four 10 Mbps hubs between
any two devices on your network, as shown below.
Front Panel
1
16 or 24 RJ-45 10/100 Ports
You can use these ports to connect 10BASE-T or 100BASE-TX devices
(workstations and other equipment) to the Baseline Dual Speed Hub. As
the ports are autosensing, the speed of the ports is determined
automatically when you connect your equipment.
WARNING:
RJ-45 Ports. These are shielded RJ-45 data sockets.
They cannot be used as standard traditional telephone sockets,
or to connect the unit to a traditional PBX or public telephone
network. Only connect RJ-45 data connectors, network
telephony systems, or network telephones to these sockets.
Either shielded or unshielded data cables with shielded or
unshielded jacks can be connected to these data sockets.
AVERTISSEMENT:
Points d’accès RJ-45. Ceux-ci sont protégés
par des prises de données. Ils ne peuvent pas être utilisés comme
prises de téléphone conventionnelles standard, ni pour la
connection de l’unité à un réseau téléphonique central privé ou
public. Raccorder seulement connecteurs de données RJ-45,
systèmes de réseaux de téléphonie ou téléphones de réseaux à
ces prises.
Il est possible de raccorder des câbles protégés ou non protégés
avec des jacks protégés ou non protégés à ces prises de
données.
WARNHINWEIS:
RJ-45-Porte. Diese Porte sind geschützte
Datensteckdosen. Sie dürfen weder wie normale traditionelle
Telefonsteckdosen noch für die Verbindung der Einheit mit
einem traditionellem privatem oder öffentlichem Telefonnetzwerk
gebraucht werden. Nur RJ-45-Datenanscluße, Telefonnetzsysteme
or Netztelefone an diese Steckdosen anschließen.
Entweder geschützte oder ungeschützte Buchsen dürfen an diese
Datensteckdosen angeschlossen werden.
Connect one end of the TP (twisted pair) cable to the RJ-45 port on the
Baseline Dual Speed Hub and the other end to the appropriate RJ-45 port
on the device. Use either shielded or unshielded data cables (with shielded
or unshielded jacks) to connect to the devices.
The equipment that is connected to the Baseline Dual Speed
Hub must not be set to operate in full duplex mode. It must be
set to operate in autonegotiate or half duplex mode.
10BASE-T
To connect 10BASE-T equipment, use 10BASE-T Category 3 or Category 5
unshielded or shielded (screened) 100 Ohm TP cable.
Category 5 cable should be used with this product in structured
wiring environments. This will ensure correct operation of all
ports at 10 Mbps or 100 Mbps.
Ethernet Network Configuration Rules
To remain within IEEE 802.3 10 Mbps Ethernet rules, the maximum length
of cable between the Baseline Dual Speed Hub and an attached device
must not exceed 100 m (328 ft). If you are connecting multiple hubs in
1
100BASE-TX
To connect 100BASE-TX equipment, use 100BASE-TX Category 5
unshielded or shielded (screened) 100 Ohm TP cable.
Fast Ethernet Network Configuration Rules
To remain within IEEE 802.3 100 Mbps Fast Ethernet rules, the maximum
length of cable between the Baseline Dual Speed Hub and an attached
device must not exceed 100 m (328 ft). Ensure that there are no more
than two 100 Mbps hubs between any two devices on your network, and
that the
total
cable distance (A+B+C) between the two devices does not
exceed 205 m (672.4 ft), as shown below.
If you connect two Baseline Dual Speed Hubs together, the link
between them operates at 100 Mbps.
2
MDI Switch
This switch affects port 16 (3C16410) or port 24 (3C16411). Ports 1–15
(3C16410) or 1–23 (3C16411) are fixed as MDIX ports. Each can be
connected to a device with an MDI port (such as most workstations) using
a normal “straight through” TP cable. Port 16 or 24 is “switch selectable”
using the MDI switch:
Out
In this position, port 16 or 24 is an MDIX port. It can be
connected to a device with an MDI port (such as most
workstations) using a normal “straight through” TP cable.
In this position, port 16 or 24 is an MDI port.
It can be connected to an MDIX port on a device (such as
another hub) using a normal “straight through” TP cable.
MDIX
In
MDI
Unit 1
13
4 5
8 9
16
17
Set switch to
MDI (in)
12
Unit 2
1
20 21
13
4
5
24
16
17
8
9
20 2
1
12
24
Switch set to MDIX (out)
if port 24 used
2
To connect the hub to a 10 Mbps or 100 Mbps unit, connect an MDIX
port on the unit to port 16 or 24 on the Hub. Ensure that the MDI switch
on the Hub is in (MDI). If an MDI/MDIX port is used on the other unit,
ensure that the MDI switch for that port is out (MDIX). Alternatively, you
can use “cross-over” TP cable to connect any MDIX port on the Baseline
Dual Speed Hub to any MDIX port on another unit.
Positioning the Baseline Dual Speed Hub
!
CAUTION:
When installing the Baseline Dual Speed Hub in a
stack of different size units, the Baseline Dual Speed Hub must
be installed above any larger units. Do not have a free standing
stack of more than six units.
3
Status LEDs
When deciding where to position the Baseline Dual Speed Hub ensure:
It is accessible and cables can be connected easily.
Cabling is away from:
The Status LEDs show the state of a port and whether or not the Link
Pulse signal is present on the segment connected to a port:
Green
Yellow
Flashing
Off
A 100 Mbps Link Pulse signal is being received and the
100BASE-TX segment attached to the port is functional.
A 10 Mbps Link Pulse signal is being received and the 10BASE-T
segment attached to the port is functional.
Packets are being received on the port.
The Link Pulse signal is not being received. Either nothing is
connected to the port, or there is a problem:
Sources of electrical noise such as radios, transmitters and broad-
band amplifiers.
Power lines and fluorescent lighting fixtures.
Water or moisture cannot enter the case of the unit.
Air flow around the unit and through the vents in the side of the case
is not restricted (3Com recommends that you provide a minimum of
25 mm (1 in.) clearance).
To prolong the operational life of your units:
Never stack units more than six high if free standing, and ensure that
cables are supported so that they do not cause the stack to fall over.
Do not place objects on top of any unit or stack.
Do not obstruct any vents at the sides of the case.
Check that the attached device is powered on.
Check that the cable is the correct type and is not faulty.
If the LED is off for port 16 or 24, check the setting of the MDI
switch. Refer to
2.
Try toggling the MDI switch.
If you have connected different types of unit together, check that
your configuration conforms to the network configuration rules
for 10BASE-T and 100BASE-TX.
If the port is connected to another unit’s MDI/MDIX port, check
the other unit’s MDI switch position.
Power Supply
Power problems can be the cause of serious failures and downtime in
your network. Ensure that the power input to your system is clean and
free from sags and surges to avoid unforeseen network outages. 3Com
recommends that you install power conditioning, especially in areas prone
to black outs, power dips and electrical storms.
The unit is intended to be grounded. Ensure it is connected to earth
ground during normal use. Installing proper grounding helps to avoid
damage from lightning and power surges.
If these checks do not identify the cause of a problem, it may be that the
unit or the device connected to the port is faulty. Contact your supplier
for further advice.
4
Collision LEDs
The Collision LEDs indicate activity on the 10 Mbps and 100 Mbps
segments:
Flashing
yellow
Collisions are occurring on the segment. A low level of collisions is
a part of normal Ethernet and Fast Ethernet operation. Excessive
collisions may indicate a network problem.
There is no collision on the segment.
Rack Mounting
The Baseline Dual Speed Hub can be mounted in a 19-in. equipment rack.
Refer to the “Mounting Kit Instructions” section in this guide.
Off
Power Up
Use the following sequence to power up the Baseline Dual Speed Hub:
1
2
3
Check the network connections and cables.
Connect the power supply cable to the appropriate power socket on
the rear panel of the unit; refer to
6.
Connect the plug to the power supply outlet socket.
5
Power LED
The Power LED indicates a number of conditions:
Green
Off
The unit is powered on and ready for use.
The unit is powered off.
The power cable may be connected incorrectly or the fuse within
the power cord’s plug may be faulty (UK models only).
If the unit appears to be operating and the LED is off, contact
your supplier.
When the Baseline Dual Speed Hub is powered on, the Power LED should
be lit. If it is not, refer to
5,
“Power LED”.
Rear Panel Connections
6
Power Supply
The Baseline Dual Speed Hub automatically adjusts to the supply voltage.
Only use the power cord that is supplied with the Baseline Dual Speed
Hub, or a power cord of the same type and rating.
7
Self-adhesive Pads
The hub is supplied with four standard height, self-adhesive rubber pads.
You do not need to apply the pads if you intend to rack mount
the unit.
If you are placing the units one on top of the other, you must use the
self-adhesive rubber pads supplied. Apply the pads to the underside of
each unit, sticking one in the marked area at each corner. Place the units
on top of each other, ensuring that the pads of the upper unit line up
with the recesses of the lower unit.
3
S
AFETY
I
NFORMATION
Please read the following safety information carefully before
installing the Baseline Dual Speed Hub.
WARNING:
Installation and removal of the unit must be carried out by
qualified personnel only.
The unit must be connected to an earthed (grounded) outlet to comply with
international safety standards.
Do not connect the unit to an A.C. outlet (power supply) without an earth
(ground) connection.
The appliance coupler (the connector to the unit and not the wall plug) must
have a configuration for mating with an EN60320/IEC320 appliance inlet.
The socket outlet must be near to the unit and easily accessible. You can only
remove power from the unit by disconnecting the power cord from the
outlet.
This unit operates under SELV (Safety Extra Low Voltage) conditions according
to IEC 60. The conditions are only maintained if the equipment to which it is
connected also operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT
supplies. If your supplies are of IT type, this
unit must be powered by 230V (2P+T) via an isolation transformer ratio 1:1, with the
secondary connection point labelled Neutral, connected directly to earth (ground).
Impédance à la terre
Power Cord Set
This must be approved for the country where it will be used. e.g.
U.S.A. and
Canada
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
No. 18 AWG
Type SV or SJ
3-conductor
The cord set must have a rated current capacity of at least
10A.
The attachment plug must be an earth-grounding type with a
NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V)
configuration.
The supply plug must comply with Section 107-2-D1,
Standard DK2-1a or DK2-5a.
The supply plug must comply with SEV/ASE 1011.
The supply plug must comply with BS1363 (3-pin 13-amp)
and be fitted with a 5 A fuse which complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and be
of type HO3VVF3GO.75 (minimum).
The supply plug must comply with CEE7/7 (“SCHUKO”)
The mains cord must be <HAR> or <BASEC> marked and be
of type HO3VVF3GO.75 (minimum).
Denmark
Switzerland
UK
Europe
L’
INFORMATION DE
S
ÉCURITÉ
I
MPORTANTE
Veuillez lire à fond l'information de la sécurité suivante avant
d'installer le Baseline Dual Speed Hub.
AVERTISSEMENT:
L’installation et la dépose de ce groupe doivent être
confiés à un personnel qualifié.
Ne branchez pas votre appareil sur une prise secteur (alimentation électrique)
lorsqu'il n'y a pas de connexion de mise à la terre (mise à la masse).
Vous devez raccorder ce groupe à une sortie mise à la terre (mise à la masse)
afin de respecter les normes internationales de sécurité.
Le coupleur d’appareil (le connecteur du groupe et non pas la prise murale)
doit respecter une configuration qui permet un branchement sur une entrée
d’appareil EN60320/IEC 320.
La prise secteur doit se trouver à proximité de l’appareil et son accès doit être
facile. Vous ne pouvez mettre l’appareil hors circuit qu’en débranchant son
cordon électrique au niveau de cette prise.
L’appareil fonctionne à une tension extrêmement basse de sécurité qui est
conforme à la norme IEC60950. Ces conditions ne sont maintenues que si
l’équipement auquel il est raccordé fonctionne dans les mêmes conditions.
France et Pérou uniquement:
Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos
alimentations sont du type impédance à la terre, ce groupe doit être alimenté par
une tension de 230 V (2 P+T) par le biais d’un transformateur d’isolement à rapport
1:1, avec un point secondaire de connexion portant l’appellation Neutre et avec
raccordement direct à la terre (masse).
Danemark
Suisse
Europe
Cordon électrique
Il doit être agréé dans le pays d’utilisation.
Etats-Unis
et Canada
Le cordon doit avoir reçu l’homologation des UL et un
certificat de la CSA.
Le cordon souple doit respecter, à titre minimum, les
spécifications suivantes:
calibre 18 AWG
type SV ou SJ
à 3 conducteurs
Le cordon doit être en mesure d’acheminer un courant
nominal d’au moins 10 A.
La prise femelle de branchement doit être du type à mise à
la terre (mise à la masse) et respecter la configuration NEMA
5-15P (15 A, 125 V) ou NEMA 6-15P (15 A, 250 V).
La prise mâle d’alimentation doit respecter la section 107-2
D1 de la norme DK2 1a ou DK2 5a.
La prise mâle d’alimentation doit respecter la norme SEV/ASE
1011.
La prise secteur doit être conforme aux normes CEE 7/7
(“SCHUKO”)
LE cordon secteur doit porter la mention <HAR> ou
<BASEC> et doit être de type HO3VVF3GO.75 (minimum).
W
ICHTIGE
S
ICHERHEITSINFORMATIONEN
Bitte unbedingt vor dem Einbauen des Baseline Dual Speed Hub
Einheit die folgenden Sicherheitsanweisungen durchlesen.
WARNUNG:
Die Installation und der Ausbau des Geräts darf nur durch
Fachpersonal erfolgen.
Das Gerät nicht an eine Wechselstromsteckdose anschließen, die nicht
geerdet ist.
Das Gerät muß an eine geerdete Steckdose angeschlossen werden, die die
internationalen Sicherheitsnormen erfüllt.
Der Gerätestecker (der Anschluß an das Gerät, nicht der
Wandsteckdosenstecker) muß eine passende Konfiguration für einen
Geräteeingang gemäß EN60320/IEC320 haben.
Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein.
Die Stromversorgung des Geräts kann nur durch Herausziehen des
Gerätenetzkabels aus der Netzsteckdose unterbrochen werden.
Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen
(Sicherheitskleinstspannung) gemäß IEC 60. Diese Bedingungen sind nur
gegeben, wenn auch die an das Gerät angeschlossenen Geräte unter
SELV-Bedingungen betrieben werden.
Stromkabel
Dies muss von dem Land, in dem es benutzt wird geprüft werden:
Schweiz
Europe
Dieser Stromstecker muß die SEV/ASE 1011Bestimmungen
einhalten.
Das Netzkabel muß vom Typ HO3VVF3GO.75
(Mindestanforderung) sein und die Aufschrift <HAR> oder
<BASEC> tragen.
Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”).
4
M
OUNTING
K
IT
I
NSTRUCTIONS
The Baseline Dual Speed Hub is supplied with two mounting brackets and
four screws. These are used for rack mounting the unit. When mounting
the unit, you should take note of the guidelines given in “Positioning the
Baseline Dual Speed Hub”on page 3.
The Baseline Dual Speed Hub is 1U high and will fit a standard 19-inch
rack.
CAUTION:
Disconnect all cables from the unit before continuing.
Remove the self-adhesive pads from the underside of unit, if
already fitted.
To rack mount the unit:
1
2
3
4
5
6
Place the unit the right way up on a hard, flat surface with the
front facing towards you.
Locate a mounting bracket over the mounting holes on one side of
the unit, as shown in the diagram.
Insert the two screws supplied in the mounting kit and fully tighten
with a suitable screwdriver.
Repeat the two previous steps for the other side of the unit.
Insert the unit into the 19-in. rack and secure with suitable screws
(not provided).
Reconnect all cables.
P
ROBLEM
S
OLVING
Refer to the information about LEDs given earlier in this guide to see if
the problem can be identified and rectified. If the problem persists and
the Baseline Dual Speed Hub still does not operate successfully, contact
your supplier with the following information before returning the unit:
Product number and serial number
(printed on a label on the rear of the unit)
A brief description of the fault
When returning any equipment to your supplier ensure that the
equipment is packed suitably for transit.
Some older NIC (network interface card) cards were developed
before the standardization of the auto-negotiation protocol.
These may cause the Baseline Dual Speed Hub to sense the
speed of the network incorrectly. We strongly recommend that
you install the latest versions of the NIC drivers before
connecting your network. 3Com NIC card drivers dated before
23/03/95 should be updated from the 3Com website.
T
ECHNICAL
I
NFORMATION
Related Standards
The SuperStack 3 Baseline Dual Speed Hub has been designed to the
following standards:
Functional
Safety
EMC Emissions
ISO/IEC 8802-3, IEEE 802.3, IEEE 802.3u, IEEE 802.1D
UL 1950, EN 60950, CSA 22.2 #950, IEC 60950
EN 55022 Class A, VCCI Class A, AS/NZS 3548 Class A,
FCC Part 15 Class A, ICES-003 Class A, CNS 13438,
EN61000-3-3, EN61000-3-2.
EN55024
Power Dissipation
Input Voltage
Current Rating
Electrical
Power Inlet
AC Line Frequency
Power Consumption
IEC 320
50/60 Hz
3C16410: 8.5 VA
3C16411: 9.5 VA
3C16410: 29 BTU/hr
3C16411: 32.4 BTU/hr
100–240 V AC
3C16410: 1.0 A (maximum)
3C16411: 1.0 A (maximum)
Immunity
Physical
Width
Depth
Height
Weight
Mounting
440 mm (17.3 in.)
173 mm (6.8 in.)
44 mm (1.7 in.) or 1 U
3C16410: 2.22 kg (4.90 lb)
3C16411: 2.6 kg (5.8 lb)
Free standing, or 19 in. rack mounted using the mounting
kit supplied
Environmental
Operating Temperature
Humidity
0–40 °C (32–104 °F)
0–95 % (non-condensing)
5